Battery Specifications
Battery Type links to more detail
12 Volt Leisure Range

Battery
Type
Capacity
20 Hr Cn
Dimensions
Length
Width
Height
695HZ
230
517
276
240
698Z
180
515
220
224
RR0
40
241
173
200
RR1
50
241
173
200
RR2
96
352
175
226
RR3
80
352
175
226

Recharging the Leisure Battery
The batteries are charged at a current equivalent to 0.1 times the capacity expressed in Ampere hours (Ah) for a maximum of 15 hours. (12 - 13 hours would normally be sufficient with a constant current charger, but 15 hours may be necessary with a taper charger.)

The duration of the recharge will depend on the extent of the discharge that the battery has experienced. As an example the 50 Ah type RR1 battery that has been utilised for 3 hours for lighting a 100W lamp would have consumed 24.9 Ah and therefore must be charged at 5 Ampere for approximately 6 hours.